Radiology · 510(k) · 2017

Arterys Cardio DL

ARTERYS INC.. Cleared by FDA on 5 January 2017 under submission K163253, product code LLZ (system, image processing, radiological). What FDA's record says, in FDA's words.

Device record · K163253

  1. Device. Arterys Cardio DLDEVICE
  2. Company. ARTERYS INC.COMPANY
  3. Decision. 5 January 2017, 510(k), substantially equivalent (traditional review); received 18 November 2016DECISION
  4. Panel. RadiologyPANEL
  5. Product code. LLZ, System, Image Processing, RadiologicalCODE
  6. Regulation. 21 CFR 892.2050, Class IIREG
  7. Source. FDA database entry · decision document (8 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

Arterys Cardio DL consists of software that analyzes DICOM-compliant cardiovascular images acquired from magnetic resonance (MR) scanners. Arterys Cardio DL specifically analyzes the blood flow to the heart and its major vessels using multi-slice, multi-phase and velocity encoded MR images. It provides clinically-relevant and reproducible, quantitative data, and it has been tested and validated on MR images acquired from both 1.5T and 3.0 T MR Scanners. The data produced by Arterys Cardio DL is intended to be used to support qualified cardiologist, radiologist, or other licensed professional healthcare practitioners for clinical decision-making. It is a support tool that provides relevant clinical data as a resource to the clinician and is not intended to be a source of medical advice or to determine or recommend a course of action or treatment for a patient. Page 19 Arterys Inc., Traditional 510(k)

K163253, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 19,970 reports filed against devices carrying product code LLZ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101631

Philips received a complaint on the IntelliSpace Cardiovascular (ISCV) indicating that the ISCV could only be accessed in Web-Only mode on the workstation. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint ((b)(4)).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101632

Philips received a complaint on the IntelliSearch Cardiovascular (ISCV) indicating that customer reported that study retrieval from the archive was either failing or taking an excessively long time to complete. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint (b)(4).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101634

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on […]

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101635

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user could not save the findings. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this […]

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101636

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user reported that it was not possible to view previous studies in Echo Module. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it […]

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code LLZ, in Radiology, from ARTERYS INC., or cleared in 2017. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files