Hematology · 510(k) · 2010

EASYCELL CELL LOCATOR

MEDICA CORP.. Cleared by FDA on 12 May 2010 under submission K092116, product code JOY (device, automated cell-locating). What FDA's record says, in FDA's words.

Device record · K092116

  1. Device. EASYCELL CELL LOCATORDEVICE
  2. Company. MEDICA CORP.COMPANY
  3. Decision. 12 May 2010, 510(k), substantially equivalent (traditional review); received 14 July 2009DECISION
  4. Panel. HematologyPANEL
  5. Product code. JOY, Device, Automated Cell-LocatingCODE
  6. Regulation. 21 CFR 864.5260, Class IIREG
  7. Source. FDA database entrySOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement could not be read from a public decision document for this submission on the retrieval date (the document is absent, scanned without text, or filed under another number). FDA's database entry is the place to read it.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 18 reports filed against devices carrying product code JOY. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

28 July 2026 · Malfunction · CellaVision DC-1 with CellaVision DM Software DC-1 Version 7.2 · CellaVision AB · report 3003630693-2026-00003

21 July 2026 · Malfunction · AUTOMATED DIGITAL CELL MORPHOLOGY ANALYZER DI-60 · CELLAVISION AB · report 3003630693-2026-00002

26 June 2026 · Malfunction · AUTOMATED DIGITAL CELL MORPHOLOGY ANALYZER DI-60 · CELLAVISION AB · report 3003630693-2026-00001

A SOFTWARE DEFECT HAS BEEN IDENTIFIED IN CELLAVISION DM SOFTWARE VERSION 7.2.0.7 WHEN USED ON CERTAIN WINDOWS 10 SYSTEMS WITH SIMPLIFIED CHINESE AS THE WINDOWS LANGUAGE DURING SMEAR REVIEW IN THE REVIEW SOFTWARE. THE DEFECT AFFECTS THE INTERPRETATION OF MANUALLY ENTERED PLATELET (PLT) COUNTS FOR THE METHOD "COUNT PLTS PER GRID SQUARE". THE SOFTWARE MAY INCORRECTLY PROCESS NUMERICAL INPUTS DUE TO INPUT METHOD EDITOR (IME) BEHAVIOUR, SPECIFICALLY, THE LAST DIGIT IN MULTI-DIGIT VALUES CAN BE […]

8 October 2025 · Malfunction · AUTOMATED DIGITAL CELL MORPHOLOGY ANALYZER DI-60 · CELLAVISION AB · report 3003630693-2025-00001

DURING ROUTINE OPERATION OF THE DI-60 ANALYZER (IN A LAB IN FRANCE) AN ERROR WAS OBSERVED IN SLIDE IDENTIFICATION. AFTER ANALYZING SLIDE 1 (WITH QR CODE) AND PLACING IT IN THE RETURN POSITION, THE ANALYZER ATTEMPTED TO READ THE BARCODE OF SLIDE 2 (WITHOUT QR CODE) BUT INSTEAD RE-READ THE QR CODE OF SLIDE 1. CONSEQUENTLY, BOTH SLIDES WERE ASSIGNED THE SAME QR CODE. THE ISSUE WAS DISCOVERED BY THE OPERATOR/HEALTHCARE PROFESSIONAL AT THE TIME OF EVENT AND THUS NO INCORRECT RESULTS WERE REPORTED. […]

5 November 2024 · Malfunction · CYTOVISION · LEICA BIOSYSTEMS · report 1419341-2024-00012

ON OCT 8TH THE CUSTOMER REPORTED AN ERROR LOADING & UNLOADING, FAILING TO MOVE TO CORRECT LOCATION ON THE STAGE AND SCANS OF A PREVIOUSLY SCANNED/CAPTURED SLIDE WHEN THE SYSTEM SAYS IT'S ON A SUBSEQUENT SLIDE FOR MATERIAL 23GSLXXXKFXUPG FOR CYTOVISION SN# (B)(6). NO LOSS OF PATIENT DATA.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code JOY, in Hematology, or cleared in 2010. The whole record is at FDA AI-enabled medical devices.