Obstetrics and Gynecology · 510(k) · 2026

Embryo Predict

Alife Health. Cleared by FDA on 15 May 2026 under submission K250781, product code PBH (embryo image assessment system, assisted reproduction). What FDA's record says, in FDA's words.

Device record · K250781

  1. Device. Embryo PredictDEVICE
  2. Company. Alife HealthCOMPANY
  3. Decision. 15 May 2026, 510(k), substantially equivalent (traditional review); received 14 March 2025DECISION
  4. Panel. Obstetrics and GynecologyPANEL
  5. Product code. PBH, Embryo Image Assessment System, Assisted ReproductionCODE
  6. Regulation. 21 CFR 884.6195, Class IIREG
  7. Source. FDA database entry · decision document (19 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

Embryo Predict is indicated to analyze images of Day 5, 6, and 7 blastocyst-stage embryos (early, expanded, hatching, and hatched) cultured in vitro that have been deemed suitable for transfer by the embryologist. The device uses patient metadata (patient age, day of embryo culture) and a software algorithm to analyze features of the blastocyst morphology and provides adjunctive information to aid in the assessment of blastocysts when there are multiple embryos deemed suitable for transfer or freezing based on standard morphological assessment. The device is intended for analysis of blastocyst stage embryos prior to biopsy and cryopreservation.

K250781, FDA decision document · source

The product code's definition, from FDA's classification record. The device will obtain and analyze light microscopy images of developing embryos. This device provides information to aid in the selection of embryo(s) for transfer when there are multiple embryos deemed suitable for transfer or freezing .

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 1 report filed against devices carrying product code PBH. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

21 June 2019 · Malfunction · EMBRYO REPLACEMENT CATHETER, SURE-PRO, WALLACE, + OBTURATOR · SMITHS MEDICAL ASD, INC. · report 3012307300-2019-03611

INFORMATION WAS RECEIVED THAT A THE "POCKET" ON A SMITHS MEDICAL EMBRYO REPLACEMENT CATHETER, SURE-PRO, WALLACE, + OBTURATOR "IS NOT CLOSED. NOT STERILIZED". NO ADVERSE EFFECTS WERE REPORTED.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.