Radiology · 510(k) · 2023
MR DWI/FLAIR Measurement V1.0
Olea Medical. Cleared by FDA on 26 April 2023 under submission K230552, product code LLZ (system, image processing, radiological). What FDA's record says, in FDA's words.
Device record · K230552
- Device. MR DWI/FLAIR Measurement V1.0DEVICE
- Company. Olea Medical (FR)COMPANY
- Decision. 26 April 2023, 510(k), substantially equivalent (traditional review); received 28 February 2023DECISION
- Panel. RadiologyPANEL
- Product code. LLZ, System, Image Processing, RadiologicalCODE
- Regulation. 21 CFR 892.2050, Class IIREG
- Source. FDA database entry · decision document (8 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
MR DWI/FLAIR Measurement V1.0 is an image processing application indicated for use in the analysis of: (1) MR Diffusion-weighted imaging (DWI) (2) MR FLAIR images. The device is intended to be used by trained professionals with medical imaging education including, but not limited to, physicians and medical technicians in the imaging assessment workflow: • computation of the map relative to the water diffusion, i.e., ADC map; • extraction and communication of metrics derived from the above map, i.e., hypointense area on ADC, and FLAIR series as well as ratios with contralateral information on FLAIR images. The results of MR DWI/FLAIR Measurement V1.0 are intended to be used in conjunction with other patient information and, based on professional judgment, to assist the clinician in the medical imaging assessment. Trained professionals are responsible for viewing the full set of native images per the standard of care. The device does not alter the original medical image. MR DWI/FLAIR Measurement V1.0 is not intended to be used as a standalone diagnostic device and shall not be used to take decisions with diagnosis or therapeutic purposes. Patient management decisions should not solely be based on MR DWI/FLAIR Measurement V1.0 results. MR DWI/FLAIR Measurement V1.0 can be integrated and deployed through technical platforms responsible for transferring, storing, converting formats, notifying of detected image variations and display of DICOM imaging data. B. Technological […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedMRI
- Mentionsan adjunct to the clinician, not a replacement
- Mentionstriage or notification
- Mentionsdetection or identification of findings
- Mentionsmeasurement or quantification
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 19,970 reports filed against devices carrying product code LLZ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101631
Philips received a complaint on the IntelliSpace Cardiovascular (ISCV) indicating that the ISCV could only be accessed in Web-Only mode on the workstation. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint ((b)(4)).Philips has started an investigation of this complaint.
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101632
Philips received a complaint on the IntelliSearch Cardiovascular (ISCV) indicating that customer reported that study retrieval from the archive was either failing or taking an excessively long time to complete. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint (b)(4).Philips has started an investigation of this complaint.
30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101634
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on […]
30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101635
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user could not save the findings. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this […]
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101636
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user reported that it was not possible to view previous studies in Echo Module. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it […]
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code LLZ, in Radiology, from Olea Medical, or cleared in 2023. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.