Cardiovascular · 510(k) · 2019
RhythmAnalytics
Biofourmis Singapore Pte. Ltd.. Cleared by FDA on 7 March 2019 under submission K182344, product code DQK (computer, diagnostic, programmable). What FDA's record says, in FDA's words.
Device record · K182344
- Device. RhythmAnalyticsDEVICE
- Company. Biofourmis Singapore Pte. Ltd. (SG)COMPANY
- Decision. 7 March 2019, 510(k), substantially equivalent (traditional review); received 28 August 2018DECISION
- Panel. CardiovascularPANEL
- Product code. DQK, Computer, Diagnostic, ProgrammableCODE
- Regulation. 21 CFR 870.1425, Class IIREG
- Source. FDA database entry · decision document (8 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
RhythmAnalytics is a software application for the assessment of cardiac arrhythmias using single-lead ECG data in subjects over 18 years of age. It is intended for use by a healthcare solution integrator to build web or mobile applications to let qualified healthcare professionals review and confirm the analytic result. The product supports downloading and analysing data recorded in compatible formats from any FDA cleared device used for the arrhythmia diagnostics such as Holter, event recorder, or other similar devices when assessment of the rhythm is necessary. RhythmAnalytics can also be electronically interfaced, and perform analysis with data transferred from other computer based ECG systems, such as an ECG management system. RhythmAnalytics provides ECG signal processing and analysis, QRS and Ventricular Ectopic Beat detection, QRS feature extraction, interval measurement, heart rate measurement, and rhythm analysis. RhythmAnalytics is not for use in life supporting or sustaining systems or ECG monitor and Alarm devices. The product can be integrated into medical devices. In this case, the medical device manufacturer will identify the indication for use depending on the application of their device. RhythmAnalytics interpretation results are not intended to be the sole means of diagnosis. It is offered to physicians and clinicians on an advisory basis only in conjunction with the physician’s knowledge of ECG patterns, patient background, clinical history, symptoms, and […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedECG
- Mentionsdetection or identification of findings
- Mentionsmeasurement or quantification
- Mentionsa diagnostic claim
- Mentionsadult patients
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 4,558 reports filed against devices carrying product code DQK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
30 September 2026 · Malfunction · QUANTIEN · Abbott Medical · report 2184149-2026-00257
During a fractional flow reserve procedure with QUANTIEN, it was noted that the PA signals were not appearing on the monitor leading to the procedure being cancelled. There were no adverse patient consequences.
29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18928
29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18932
29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18933
29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18934
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code DQK, in Cardiovascular, from Biofourmis Singapore Pte. Ltd., or cleared in 2019. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.