Clinical Toxcicology · 510(k) · 2018

Tissue of Origin Test Kit-FFPE

Cancer Genetics, Inc.. Cleared by FDA on 15 March 2018 under submission K173839, product code OIW (software, similarity score algorithm, tissue of origin for malignant tumor types). What FDA's record says, in FDA's words.

Device record · K173839

  1. Device. Tissue of Origin Test Kit-FFPEDEVICE
  2. Company. Cancer Genetics, Inc.COMPANY
  3. Decision. 15 March 2018, 510(k), substantially equivalent (special review); received 18 December 2017DECISION
  4. Panel. Clinical ToxcicologyPANEL
  5. Product code. OIW, Software, Similarity Score Algorithm, Tissue Of Origin For Malignant Tumor TypesCODE
  6. Regulation. 21 CFR 862.3100, Class IIREG
  7. Source. FDA database entry · decision document (9 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

Indication for Use: The Cancer Genetics Tissue of Origin Test is an in vitro diagnostic intended to measure the degree of similarity between the RNA expression patterns in a patient's formalin-fixed, paraffin-embedded (FFPE) tumor and the RNA expression patterns in a database of fifteen tumor types (poorly differentiated, undifferentiated and metastatic cases) that were diagnosed according to then current clinical and pathological practice. This test should be evaluated by a qualified physician in the context of the patient's clinical history and other diagnostic test results.

K173839, FDA decision document · source

The product code's definition, from FDA's classification record. This test is intended to measure the degree of similarity between the RNA expression pattern in a patient?s fresh-frozen tumor and the RNA expression patterns in a database of tumor samples for some common malignant tumor types that were diagnosed according to then current clinical and pathological practice. The test result is intended for use in the context of the patient?s clinical history and other diagnostic tests evaluated by a qualified clinician. The test is not intended to establish the origin of tumors (e.g. carcinoma of unknown primary) that cannot be diagnosed according to current clinical and pathological practice.

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 0 reports filed against devices carrying product code OIW. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code OIW, in Clinical Toxcicology, or cleared in 2018. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files