Radiology · 510(k) · 2025
Vivid iq
GE Medical Systems Ultrasound and Primary Care Diagnostics. Cleared by FDA on 11 February 2025 under submission K243620, product code IYN (system, imaging, pulsed doppler, ultrasonic). What FDA's record says, in FDA's words.
Device record · K243620
- Device. Vivid iqDEVICE
- Company. GE Medical Systems Ultrasound and Primary Care DiagnosticsCOMPANY
- Decision. 11 February 2025, 510(k), substantially equivalent (traditional review); received 22 November 2024DECISION
- Panel. RadiologyPANEL
- Product code. IYN, System, Imaging, Pulsed Doppler, UltrasonicCODE
- Regulation. 21 CFR 892.1550, Class IIREG
- Source. FDA database entry · decision document (9 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
, however the proposed device Vivid iq is adding Vascular Access which has been cleared on reference device Vivid S70N/S60N (K220619). Transducers: The proposed Vivid iq and predicate Vivid iq (K221148) transducers are similar, except for: Addition of two OEM Ultrasound Catheters (AcuNav Crystal Ultrasound Catheter (K233270) from SIEMENS Medical Solutions USA, Inc and SOUNDS TARTM CRYSTAL Ultrasound Catheter (K240050) from Biosense Webster Inc.) to the compatible accessory list. The clinical indications and modes on the proposed Vivid iq are the same as on the pred icate device Vivid iq (K221148) Software Features/Functionality: Sleep mode: similar to Standby mode on cleared LOGIQ e (K232186). It helps reduce battery consumption and allows for longer time between battery ch arges, enabling up to 22% reduced daily power consumption and 22% extended portable echo usage. Clarity +: s imilar to Advanced SRI-HD on cleared LOGIQ Fortis (K211524), it is a real-time image processing/filtering technique that suppresses noise and graininess (reduces speckles) while sharpening boundaries and small structures. DICOM En capsulated PDF report: allows PDF reports generated on the system to be transferred through DICOM data flows and stored in DICOM storage, in accordance with the DICOM standard. Remote Viewing: same as on cleared Vivid S70N(K220619), enables strea ming of the main monitor over the local network. This feature is not for diagnostic use. Addition of Carto 3 […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedultrasound
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 2,748 reports filed against devices carrying product code IYN. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
30 September 2026 · Malfunction · ACUSON Origin Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00096
30 September 2026 · Malfunction · ACUSON Sequoia Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00097
30 September 2026 · Malfunction · AFFINITI 30 · Philips Ultrasound, Inc · report 3019216-2026-100325
30 September 2026 · Injury · EPIQ 5G · Philips Ultrasound, Inc · report 3019216-2026-100326
29 September 2026 · Malfunction · ACUSON Juniper · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00091
One of the patient exams performed on the Juniper system displays an "Unarchived" error message and they are unable to send this study to PACS. All other exams performed before are after this one are transferring over to the PACS as expected without any errors. The problem occurred after a Breast study was completed and the user tried to send it over to the network PACS. TSE worked with the customer and she confirmed that the problem cannot be reproduced, as it only is affecting this one exam. […]